Test Code TMP Trimethoprim, Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Red top (gel tubes/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Serum for a peak level should be collected at least 60 minutes after a dose.
2. Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.
Useful For
Monitoring trimethoprim therapy to ensure drug absorption, clearance, or compliance
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Reporting Name
Trimethoprim, SSpecimen Type
Serum RedSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
>2.0 mcg/mL (Peak)
Day(s) Performed
Monday, Thursday
Report Available
2 to 5 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80299
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
TMP | Trimethoprim, S | 11005-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
80146 | Trimethoprim, S | 11005-6 |
Forms