Sign in →

Test Code LIDO Lidocaine, Serum

Methodology

Immunoassay

Performing Laboratory

Huntsville Hospital Laboratory

Specimen Requirements

Serum or plasma required. Draw blood in a plain, red-top tube(s), serum gel tube(s), heparin, EDTA or oxalate tube. Spin down and send 1 mL (pediatric:  0.2 mL) of serum.  

Store the specimen refrigerated at 2-80C. Specimen is stable for 2 hours at 2-80C For transporting, maintain the sample temperature at 2-80C.

Pharmacokinetics factors influence the correct time of sample collection after the las drug dose.  These factors include dosage form, mode of administration,concomitant drug therapy, and biological variations affecting drug disposition.

Sample collection time guidelines:

  • 12 hours after initiating prophylactic lidocaine therapy after suspected myocardial infarction, and daily thereafter during lidocaine treatment
  • at least every 12 hours in patients with evidence of cardiac or hepatic insufficiency
  • whenever lidocaine toxicity is suspected
  • whenever ventricular arrhythmias occur despite lidocaine administration

Reference Values

Therapeutic concentration:  1.5-5.0 µg/mL

Day(s) Test Set Up

Monday through Sunday

CPT Coding

80176

Secondary ID

HHA1430

LOINC Coding

Test name LOINC Code

Lidocaine, Serum

3714-3

 

Reject Due To

 

Hemolysis

Mild:

ok

Gross:

ok

Lipemia

Mild:

ok

Gross:

ok

Icterus

Mild:

ok

Gross:

Reject

 

Specimen Stability Information

See Specimen Requirements above