Test Code HOMOC Homocysteine, Total, Plasma
Methodology
Enzymatic
Performing Laboratory
Huntsville Hospital Laboratory
Specimen Requirements
Draw blood in a light green-top (lithium heparin) tube. Keep specimen on ice and centrifuge within 1 hour of collection.
Reference Values
Adults: <15.0 µmol/L
Day(s) Test Set Up
Monday through Friday
CPT Coding
83090
Secondary ID
HHA1460
LOINC Coding
Test name | LOINC Code |
---|---|
Homocysteine, Total, Plasma |
13965-9 |
Specimen Stability Information
Specimen Type |
Temperature |
Time |
Plasma, lithium heparin |
Refrigerated - separated from cells |
4 weeks |
Room Temperature - separated from cells | 4 days |
Reject Due To
Hemolysis |
Mild: |
ok |
Gross: |
Reject |
Lipemia |
Mild: |
ok |
Gross: |
Reject |
Icterus |
Mild: |
ok |
Gross: |
Reject |