Test Code HCVAB Hepatitis C Antibody (Anti-HCV) (with Reflex to HCV RNA Detection/Quantification by PCR), Serum
Methodology
Testing Algorithm:If HHA1266 “Hepatitis C Antibody (Anti-HCV)” by ECLIA is positive, then HHA1506 “Hepatitis C Virus (HCV) RNA Detection and Quantification by Real-Time Reverse Transcription-PCR (RT-PCR)” will automatically be performed at an additional charge.
Method Name:
HHA1266: Electrochemiluminescence Immunoassay
HHA1506: Real-Time Reverse Transcription-Polymerase Chain Reaction (RT-PCR)
(PCR is utilized pursuant to a license agreement with Roche Molecular Systems, Inc.)
Performing Laboratory
Huntsville Hospital Laboratory
Specimen Requirements
Draw blood in a serum gel tube(s). Aseptically spin down within 1 hour of draw and send 2 mL of serum refrigerated.
Reference Values
Nonreactive (reported as reactive or nonreactive)
Interpretation depends on clinical setting.
Day(s) Test Set Up
Monday through Sunday
CPT Coding
86803 - anti-HCV
87522 - HCV RNA detection/quantification by RT-PCR (if appropriate)
Secondary ID
HHA1266
LOINC Coding
Test Name | LOINC Code |
---|---|
Hepatitis C Antibody (Anti-HCV) | 16128-1 |
Specimen Stability Information
Specimen Type |
Temperature |
Time |
Serum | RT, spun | 3 days |
Refrigerated, spun | 7 days |
Reject Due To
Hemolysis |
Mild: |
ok |
Gross: |
Reject |
Lipemia |
Mild: |
ok |
Gross: |
Reject |
Icterus |
Mild: |
ok |
Gross: |
Reject |